Technical parameters of TVS

TVS for currents up to 150 kA/ 25 C in impulse

RVU-7 RVU-31Н RVU-31 RVU-101
Operating voltage, kV 0.05-18 0.5-35 0.5-50 3-100
Operating current, kA 0.2-80 0.2-60 0.2-60 1-60
Maximum charge per impulse, C 1 5 5 5
Service life (switches) 5•104 105 105 5•104
Triggering voltage, kV 6 6 6 8
Triggering current, not less than, A 50 100 100 300
Triggering current duration, not less than, us 0.1-2 0.2-10 0.2-10 0.2-10
Diameter, mm 50 78 100 100
Height, mm 100 220 195 346
Weight, kg 0.6 2.2 3.5 7

TVS for currents more than 150 kA/ 25 C in impulse

RVU-27 RVU-47 RVU-43-1 RVU-52 РВУ-63
Operating voltage, kV 0.3-25 0.5-45 0.5-45 0.5-40 1-55
Operating current, kA 3-200 5-250 5-400 5-600 10-700
Maximum charge per impulse, C 60 100 160 180 300
Service life (switches) 105 5•104 5•104 5•104 5•104
Triggering voltage, kV 6 6 6 6 6
Triggering current, not less than, A 300 500 500 500 500
Triggering current duration, not less than, us 5-10 5-10 5-10 5-10 5-10
Diameter, mm 102 128 145 145 163
Height, mm 122 195 197 197 216
Weight, kg 2.3 5.2 6.2 6.1 10.5